- Home > Product > Electric Drive > VFD Accessories > Output Filter and Reactor
Output Filter and Reactor
- Shielded cables.
- Lowered carrier.
- Output reactor.
- Output filter.
- Ground and shielding.
- Separate drive and motor.
Features
- Features
- Specifications
- Downloads
- Solutions
- Cases
- News
- Related Products
- Additional Information
Output Reactor Overview
The main function is to compensate for the effect of charging and discharging of the coupling capacitor when the motor is running on long cables to avoid drive over-current. It has two types: iron core reactor and ferrite reactor, which are suitable for different carrier frequency ranges. By increasing the cable distance from the drive to the motor, the output reactor effectively suppresses the instantaneous high voltage generated when the IGBT module is switched on and off, and reduces the adverse effect of this voltage on the cable insulation and the motor. At the same time, use thick or unshielded cables can also enhance the insulation strength.
Output Filter Overview
Add a filter, a sinuous filter for example to the output side of the drive to ensure that the output voltage and current waves are nearly sinusoidal, so that to reduce the motor harmonic distortion factor and insulation stress. It can effectively filter out the high harmonics in the output current, reduce the additional torque caused by high-frequency harmonics, and reduce the temperature rise and noise from the motor. Moreover, it can effectively inhibit the surge voltage from the drive to protect the motor, and improve the power factor of the frequency conversion speed control system.
Difference Between Reactor and Filter
In short, reactors protect motors and cables by limiting instantaneous high voltages and compensating for the effects of cable length, while filters improve the waveforms of output voltages and currents to reduce the effects of harmonics on motors. In frequency conversion systems, each device plays a crucial role. Please select the appropriate equipment based on specific application requirements and conditions.
Drive Output Solution
Shielded Cables
- Use shielded cables on AC drives to avoid interference to other appliances.
- A larger cable cross-sectional area enhances the cable capacity and reduces the impact of voltage drops and current fluctuations on the motor.
Lowered Carrier
Properly reduce the carrier frequency of the drive to minimize the damage to the motor insulation due to the peak voltage in each cycle.
Output Reactor
Add a reactor to the output side of the drive to effectively suppress the voltage rise rate and peak voltage, so as to reduce the voltage reflection and current waveform distortion, to weaken the damage to the motor insulation.
Output Filter
Add a dv/dt and VPL filter or a sinusoidal filter to suppress voltage and current fluctuations and interference to the motor.
Separate Signal and Power Llines
Signal lines are not arranged in parallel with power lines to minimize electromagnetic interference.
Ground and Shielding
A good grounding and shielding is ensured to reduce electromagnetic interference signals effectively for normal operation.
Separate Drive and Motor
Separate the stepper motor from the drive to reduce the mutual influence of electromagnetic interference signals.
Specifications
FWD-REACTOR-35A | Drive Power(kW): 15 Rated Current(A): 35 Weight(kg): 4.4 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.25 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 60 Efficiency(%): 79 Reactor Capacity(VA): 288 |
---|---|
FWD-REACTOR-50A | Drive Power(kW): 22 Rated Current(A): 50 Weight(kg): 6 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.18 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 80 Efficiency(%): 80 Reactor Capacity(VA): 424 |
FWD-REACTOR-80A | Drive Power(kW): 37 Rated Current(A): 80 Weight(kg): 7.2 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.08 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 95 Efficiency(%): 80 Reactor Capacity(VA): 482 |
FWD-REACTOR-125A | Drive Power(kW): 55 Rated Current(A): 125 Weight(kg): 13 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.056 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 150 Efficiency(%): 81 Reactor Capacity(VA): 824 |
FWD-REACTOR-224A | Drive Power(kW): 110 Rated Current(A): 224 Weight(kg): 19 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.028 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 230 Efficiency(%): 82 Reactor Capacity(VA): 1323 |
KDG-00075/G2 | Drive Power(kW): 0.75 Rated Current(A): 5 Weight(kg): 2 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 2.8 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 10 Efficiency(%): 55 Reactor Capacity(VA): 22 |
---|---|
KDG-0015/G2 | Drive Power(kW): 1.5 Rated Current(A): 10 Weight(kg): 2 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 1.4 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 11 Efficiency(%): 75 Reactor Capacity(VA): 44 |
KDG-0022/G2 | Drive Power(kW): 2.2 Rated Current(A): 15 Weight(kg): 2.5 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.93 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 15 Efficiency(%): 77 Reactor Capacity(VA): 66 |
KDG-0037/G2 | Drive Power(kW): 3.7 Rated Current(A): 25 Weight(kg): 3 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.56 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 16 Efficiency(%): 85 Reactor Capacity(VA): 110 |
KDG-0055/G2 | Drive Power(kW): 5.5 Rated Current(A): 37 Weight(kg): 4 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.38 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 24 Efficiency(%): 85 Reactor Capacity(VA): 163 |
KDG-0075/G2 | Drive Power(kW): 7.5 Rated Current(A): 50 Weight(kg): 6 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.25 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 29 Efficiency(%): 87 Reactor Capacity(VA): 220 |
KDG-0110/G2 | Drive Power(kW): 11 Rated Current(A): 75 Weight(kg): 7 Operating Temperature(℃): -25~45 Rated Frequency(Hz): 50Hz/60Hz Inductance(mH): 0.18 Switching Frequency(kHz): 2-4 Max. Power Loss(W): 32 Efficiency(%): 90 Reactor Capacity(VA): 318 |
XGM-2H-6A | Drive Power(kW): 1.5 Rated Current(A): 6 Weight(kg): 0.6 Operating Temperature(℃): -25~85 Rated Frequency(Hz): 10KHz~30MHz Inductance(mH): -20%*10mH~+70%*10mH Switching Frequency(kHz): 2-6 |
---|---|
XGM-2H-10A | Drive Power(kW): 2.2 Rated Current(A): 10 Weight(kg): 0.6 Operating Temperature(℃): -25~85 Rated Frequency(Hz): 10KHz~30MHz Inductance(mH): -20%*10mH~+70%*10mH Switching Frequency(kHz): 2-6 |
XGM-2H-20A | Drive Power(kW): 3.7 Rated Current(A): 20 Weight(kg): 0.8 Operating Temperature(℃): -25~85 Rated Frequency(Hz): 10KHz~30MHz Inductance(mH): -20%*10mH~+70%*10mH Switching Frequency(kHz): 2-6 |
XGM-2H-30A | Drive Power(kW): 7.5 Rated Current(A): 30 Weight(kg): 0.9 Operating Temperature(℃): -25~85 Rated Frequency(Hz): 10KHz~30MHz Inductance(mH): -20%*10mH~+70%*10mH Switching Frequency(kHz): 2-6 |
XGM-2H-50A | Drive Power(kW): 11 Rated Current(A): 50 Weight(kg): 1.5 Operating Temperature(℃): -25~85 Rated Frequency(Hz): 10KHz~30MHz Inductance(mH): -20%*10mH~+70%*10mH Switching Frequency(kHz): 2-6 |
Downloads
File Name | Type | Language | File Type | Update | Download |
---|---|---|---|---|---|
Output Filter and Reactor Catalog | Catalog | English | 2025-01-13 | 342KB |